    The Water-Recirculating Sheet Former is engineered for paper laboratories to prepare φ200 mm handsheets in compliance with QB/T 3703, ISO 5269/2, and TAPPI T-205. It features a white-water recirculation system and pneumatic mixing, achieving sheet uniformity up to ~96%. Basis weight ranges from 5 to 400 g/m², with support for external vacuum filtration. Suitable for pulp research, paper property evaluation, and process simulation, it offers efficiency, water savings, and safe operation.
  • يشارك:
  • اتصل بنا تحقيق
  • صندوق البريد:anmt_test@126.com
    واتس اب:+86 133 5666 3110

Product Introduction
The Water-Recirculating sheet former is a laboratory handsheet preparation device designed in accordance with QB/T 3703-1999, ISO 5269/2&3, TAPPI T-205 and related standards. It forms pulp into standard φ200 mm circular test sheets. The integrated automatic water-fill, white water recirculation, and air-bubble mixing system ensure uniform fiber distribution and dense sheet structure. Built with a 304 stainless steel frame and polymer wet parts, it combines corrosion resistance with ease of operation. It is well-suited for pulp evaluation, paper R&D, quality control, and educational demonstration.


Key Features
Multi-standard Compliance: Conforms to QB/T 3703-1999, ISO 5269/2&3, TAPPI T-205, and more, ensuring handsheets are produced under internationally accepted conditions.
Efficient Mixing System: Standard air-bubble mixing provides excellent fiber dispersion; manual mixing mode also available for specialty fibers and non-standard procedures.
Water Recirculation Design: White water is collected and reused for the next sheet, significantly reducing water consumption and fiber/fines loss, making long-term operation economical and eco-friendly.
200 mm Diameter Forming Cylinder: Made from high-durability polymer, rust-free and wear-resistant. Combined with silicone gaskets and mechanical cam-lock progressive pressing, it eliminates leakage and delivers clean, fuzz-free sheet edges.
Stainless Steel Construction: Frame and integrated water tank are 304 stainless steel, resistant to corrosion and easy to clean, ideal for high-frequency lab use.
Flexible Vacuum Options: Supports both natural vacuum filtration and external vacuum pump connection (pump not included), allowing users to adjust dewatering speed as needed.
Safe and Convenient: Mobile water tank with casters; manual or automatic drainage selection for flexible workflow.


Technical Specifications

Parameter

Specification

Cylinder inner diameter

200 mm

Capacity

8 L

Wire-to-overflow height

800+5 mm

Water tank material

Polymer

Screen mesh options

80 or 100 mesh

Handsheet diameter

φ200 mm

Mixing method

Manual + pneumatic

Water tank

Integrated 304 stainless steel

Water fill

Automatic recirculation

Pump head material

Stainless steel

Power

220 V, 50 Hz / 380 W

Pressing mechanism

Mechanical cam progressive press

Gasket material

Silicone

Basis weight range

5–400 g/m²

Thickness range

0.05–3 mm (fiber dependent)

Sheet uniformity

~96% (fiber dependent)

Frame material

304 stainless steel

Vacuum filtration

Natural vacuum / external vacuum (pump not incl.)

Drainage

Manual valve / automatic


FAQ
1. Uneven sheet, unstable basis weight
Fluctuating water flow, poorly dispersed stock, or unlevel screen. Pre-disintegrate pulp thoroughly, stabilize water flow, and level the screen.
2. Holes, missing edges, or tears in sheet
Undispersed fiber clumps or debris, excessively fast drainage, rough sheet removal. Fully defiber the pulp, control drainage rate, and handle wet sheets gently.
3. Water leakage from forming cylinder
Aged silicone gasket, misaligned cylinder, loose clamps. Replace gasket, align cylinder, and tighten clamps securely.
4. Weak or slow water recirculation
Clogged inlet filter or water tank, scale buildup in pump. Regularly clean filter, tank, and piping.
5. Slow vacuum dewatering, low suction
Blocked vacuum pump filter, air leaks in lines, high water level in tank. Check line seals and drain accumulated water.
6. Excessive bubbles, uneven forming
Air entrapment from overly rapid filling. Pour slurry slowly and steadily to minimize turbulence.
7. Stiff or noisy column movement
Dust buildup on guides, lack of lubrication, loose fasteners. Clean guides, apply light lubrication, and retighten screws periodically.
8. Murky water affecting subsequent sheets
Prolonged use without changing recirculated water. Drain and replace water after each experiment, flush tank and tubing.

Water-Cycle Sheet Former



العلامات ذات الصلة: handsheet former sheet machine laboratory paper making equipment

رسالة عبر الإنترنت

الرجاء إدخال عنوان بريد إلكتروني صالح
رمز التحقق لا يمكن أن يكون فارغا

المنتجات ذات الصلة

لا توجد نتائج بحث!
400-9933-057

Shandong Annimet Instruments Co., Ltd., established in 2007, is a professional manufacturer integrating R&D, production, and sales of laboratory testing instruments and sample preparation equipment. With nearly two decades of industry experience, we are committed to delivering reliable quality testing solutions to clients worldwide.

Contact Us

Contact: +86 400-9933-057 

Company Address: Factory Building 105, No. 155, Xinmao Qilu Science and Technology City, No. 299 Zidong Avenue, Tianqiao District, Jinan City, Shandong Province

E-mail: anmt_test@126.com

Fax: +86 0531-88092218

Copyright ©  2026 Shandong Annimet Instruments Co., Ltd.  All rights reserved

خريطة الموقع

يستخدم هذا الموقع ملفات تعريف الارتباط لضمان حصولك على أفضل تجربة على موقعنا.

يقبل يرفض